Natural perspective projections for head-mounted displays.

Steinicke Frank, Bruder Gerd, Kuhl Scott, Willemsen Pete, Lappe Markus, Hinrichs Klaus

Forschungsartikel (Zeitschrift) | Peer reviewed

Zusammenfassung

The display units integrated in today's head-mounted displays (HMDs) provide only a limited field of view (FOV) to the virtual world. In order to present an undistorted view to the virtual environment (VE), the perspective projection used to render the VE has to be adjusted to the limitations caused by the HMD characteristics. In particular, the geometric field of view (GFOV), which defines the virtual aperture angle used for rendering of the 3D scene, is set up according to the display field of view (DFOV). A discrepancy between these two fields of view distorts the geometry of the VE in a way that either minifies or magnifies the imagery displayed to the user. It has been shown that this distortion has the potential to affect a user's perception of the virtual space, sense of presence, and performance on visual search tasks. In this paper, we analyze the user's perception of a VE displayed in a HMD, which is rendered with different GFOVs. We introduce a psychophysical calibration method to determine the HMD's actual field of view, which may vary from the nominal values specified by the manufacturer. Furthermore, we conducted two experiments to identify perspective projections for HMDs, which are identified as natural by subjects--even if these perspectives deviate from the perspectives that are inherently defined by the DFOV. In the first experiment, subjects had to adjust the GFOV for a rendered virtual laboratory such that their perception of the virtual replica matched the perception of the real laboratory, which they saw before the virtual one. In the second experiment, we displayed the same virtual laboratory, but restricted the viewing condition in the real world to simulate the limited viewing condition in a HMD environment. We found that subjects evaluate a GFOV as natural when it is larger than the actual DFOV of the HMD--in some cases up to 50 percent--even when subjects viewed the real space with a limited field of view.

Details zur Publikation

FachzeitschriftIEEE Transactions on Visualization and Computer Graphics (TVCG)
Jahrgang / Bandnr. / Volume17
Ausgabe / Heftnr. / Issue7
Seitenbereich888-899
StatusVeröffentlicht
Veröffentlichungsjahr2011 (31.07.2011)
Sprache, in der die Publikation verfasst istEnglisch
DOI10.1109/TVCG.2010.248

Autor*innen der Universität Münster

Bruder, Gerd
Institut für Informatik
Hinrichs, Klaus
Professur für Praktische Informatik (Prof. Hinrichs)
Lappe, Markus
Professur für Allgemeine Psychologie (Prof. Lappe)
Steinicke, Frank
Institut für Informatik